Manual
HM1016ER1
Technical Specification
Harsen
®
Page 53/54
10. Technical Specification
10.1 AC voltage:
Measurement
True RMS
Phase to Neutral
15 to 346VAC
Phase to Phase
25 to 600VAC
Max power wastage per line
<0.1W
Accuracy
1%
Display
0 to 9999V
10.2 AC voltage frequency:
Input frequency
3 to 70Hz (voltage
≥
15VAC)
Accuracy
0.1%
Display
0 to 100Hz
10.3 Current (isolated):
Measurement
True RMS
Measuring current
5A
Accuracy
1%
Display
0 to 9999A
Max power wastage per line
<0.01W
10.4 Power supply:
Range
12V/24V (8-35V continuous)
Max. operating current
@12V 300mA, @24V 150mA
Max. standby current
@12V 90mA, @24V 45mA
Cranking dropouts
0V for 80ms, assuming dc supply was at least
10V before dropout and recovers to 5V
Accuracy
1%
Display
0 to 40V
10.5 Configurable digital inputs:
Number
5
Max. contact resistance
10K
Ω
Type
Isolated
Max. contact current per line
1mA
10.6 Configurable relay outputs:
Fuel relay
16A/30Vdc
Start relay
16A/30Vdc
Aux relay
3A/30Vdc