Receiver Frequency Measurement & Adjustment
1.
Record the operating frequency of the Receiver from the Keypad (hidden
menu).
CONFIGURATION > F1 + F3 or Ctrl B > RX FREQ
For 6/7 GHz radios: Enter 7 digits without the decimal point.
For 10/11 GHz radios: Enter 8 digits without the decimal point. Add zeros
(0) at the end if needed to complete the 8-digit field.
This frequency should match the one written on the Rx filter and the
station authorization.
2.
To measure the 100 MHz oscillator frequency, connect a frequency
counter to the REF MON port on the Receiver Assembly (
3.
To adjust the oscillator frequency, use the Keypad hidden-menu command
CONFIGURATION > F1 + F3 or Ctrl B > RX 100MHZ TUNE
4.
Adjust the frequency to
100.000,000 MHz
±
(see table)
Year of Operation
Tolerance
Initial adjustment
± 100 Hz
Thereafter
± 300 Hz
Summary of Contents for Constellation
Page 1: ...Point to Point Digital Radio Constellation Installation Maintenance...
Page 2: ......
Page 4: ...Constellation November 2003...
Page 18: ...Constellation November 2003 xii List of Figures...
Page 24: ...Constellation November 2003 xviii Preface...
Page 26: ...Constellation November 2003 xx Preface...
Page 96: ...Constellation November 2003 4 12 Loopback Testing...
Page 110: ...Constellation November 2003 5 14 Configuring the Constellation Radio...
Page 134: ...Constellation November 2003 7 14 SNMP Based Network Management...
Page 210: ...Constellation November 2003 11 36 Field Replaceable Units...
Page 238: ...Constellation November 2003 A 16 Wiring Specifications...
Page 260: ...Constellation November 2003 C 10 Hardware Compatibility Tables...
Page 276: ...Constellation November 2003 Glossary 6...
Page 291: ......