ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
3 – Installation & Wiring
Version 2.11, August 2011
3-14
Harris Corporation
Intraplex Products
Table 3-10 lists the pin assignments for the T1 I/O (DB-15) connector for the MA-217B module
adapter.
Table 3-10. T1 I/O Connector Pin Assignments on MA-217B
Connector
(DB-15)
Pins
Label
Description
1 (Tip) and 9
(Ring)
T1 (Tip)
R1 (Ring)
T1 Out. The balanced T1 output of the corresponding CM-5RB
module.
3 (Tip) and
11 (Ring)
T1 (Tip)
R1 (Ring)
T1 In. The balanced T1 input of the corresponding CM-5RB
module.
2, 4, 8 & 10
T1 signal grounds. These pins may be used to provide signal
ground to an external DCE such as a T1 CSU.
All other pins
Not used
Figure 3-13 shows the normal connections between the T1 I/O connector on an MA-215, MA-235-1, or
MA-235-2 module adapter and the T1 I/O connector on a channel service unit (CSU).
Figure 3-13. T1 Circuit between MA-215, MA-235-1, or MA-235-2 and CSU
Figure 3-14 shows the normal connections between the T1 I/O connector on an MA-217B and the T1
I/O connector on a channel service unit (CSU).
Figure 3-14. T1 Circuit Connection between MA-217B and CSU
Warning!
The multiplexer and the CSU must both be set to use the same T1 frame format (ESF or
SF) and line coding (B8ZS or AMI).
Summary of Contents for ACS-163
Page 4: ...This page is left blank intentionally...
Page 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...