3 – Installation & Wiring
ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation
3-11
Intraplex Products
Figure 3-9. Rear Panel Connectors on ACS-165 Using MA-215 Module Adapters
Figure 3-10. Rear Panel Connectors on ACS-168 Using MA-217B Module Adapters
If the multiplexer is not equipped for module and line redundancy, there is an MA-215 or an MA-217B
behind the CM-5RB module. Both the MA-215 and MA-217B module adapters provide T1, remote port,
and timing connectors. However, the MA-215 adapter has an RJ-48C connector for the T1 circuit, and
the MA-217B adapter has a DB-15 connector for the T1 circuit. Figure 3-11 shows the pin locations on
both module adapter connectors.
Terminal strip 1 (DC power)
Terminal strip 2 (alert and alarm relays)
MA-215 for
DI-B CM-5RB
MA-215 for
DI-A CM-5RB
Blank plate covering access
to expansion connectors
AC power in (replaced by a blank
plate if the shelf is DC powered)
Connector for alarm
signal battery
MA-217B for
DI-B CM-5RB
Available slots for module adapters
MA-217B for
DI-A CM-5RB
AC power input