4 – Setup & Configuration ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
Version 2.11, August 2011
Harris Corporation
4-3
Intraplex Products
Table 4-1. CM-5RB Basic Configuration Group
Group
Selections
Description
TSEL
TLBO
Sets the line build-out range for the T1 port on the CM-5RB module. The
display shows the midpoint of the range (Section 4.5 –
T1 Frame Format and
Line Code (TSEL Group)
).
RED = not selected, GREEN = selected
DSX
(default)
Sets build-out for DSX standard (0' to 133').
200’
Sets build-out for 133' to 266'.
333’
Sets build-out for 266' to 399'.
467’
Sets build-out for 399' to 533'.
595’
Sets build-out for 533' to 655'.
7dB
Network build-out for -7.5 decibels.
15dB
Network build-out for -15 decibels.
exit
Exits TLBO and displays sub-menu.
CSU
Channel Service Unit – Sets the standard for the CM-5RB module’s integrated
CSU (Section 4.5.1 –
CSU Configuration
).
RED = not selected, GREEN = selected
Off
Disables the integrated CSU for operation with an external CSU.
ATT
Sets the standard for the CM-5RB modules integrated CSU to AT&T TR54016
compliant.
ANSI
(default)
Sets the standard for the CM-5RB modules integrated CSU to ANSI T1.403
compliant.
exit
Exits CSU and displays sub-menu.
SF
Sets the framing format to Superframe.
RED = not selected, GREEN = selected
ESF (default)
Sets the framing format to Extended Superframe.
RED = not selected, GREEN = selected
AMI
Sets the line coding to alternate mark inversion.
RED = not selected, GREEN = selected
B8ZS (default)
Sets the line coding to B8ZS.
RED = not selected, GREEN = selected
PDE
Pulse density enforcement; for AMI mode to force a one after 15 consecutive
zeros (Section 4.5.2 –
Framing and Line Code Configuration
).
RED = not selected, GREEN = selected
TIME
Source of multiplexer’s timing (Section 4.4 –
T1 Transmitter Timing (TIME
Group)
).
RED = not selected, GREEN = selected
Loop
Loop timing of T1 link – Only displays if the CM-5RB module is in TERM mode.
Int (default)
Internal timing of T1 link – Only displays if the CM-5RB module is in TERM
mode.
Ext
External timing of T1 link – Only displays if the CM-5RB module is in TERM
mode.
Thru
Through timing of the T1 link – Only displays if the CM-5RB module is in DI-A
or DI-B mode.
Summary of Contents for ACS-163
Page 4: ...This page is left blank intentionally...
Page 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...