ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
5 – Remote Control
Version 2.11, August 2011
5-32
Harris Corporation
Intraplex Products
<SHELF STATUS>;
MODULE REDUNDANCY=<YES/NO>
LINE REDUNDANCY=<YES/NO>
MA=<STD, EIB, MA-235>
<ERROR MESSAGE 1>
<ERROR MESSAGE n>;<CR><LF>
Table 5-11 shows the channel module STATUS? message commands for line and module redundancy.
Table 5-11. ISiCL STATUS? Message
Line/Module
Redundancy
Mode
ISiCL Status
Message
ISiCL Status Message Response and Meaning
Primary,
Backup
MODULE
REDUNDANCY
YES, if your hardware is module redundancy-capable. This is always YES if using
the CM-5RB module and MA-235 module adapter.
Primary,
Backup
LINE
REDUNDANCY
YES, if your hardware is line redundancy-capable. This is always YES if using the
CM-5RB module and MA-235 module adapter.
Primary,
Backup
MA
STD, if the common module has auto-detected the MA-210/211/216/217/218
module adapter types.
MA-235 module adapter, if common module has auto-detected the MA-235-1 or
MA-235-2 adapter.
ISiCL “STATUS?” error messages support combined module and line redundancy (Table 5-12).
Table 5-12. Line/Module Redundancy ISiCL STATUS? Error Messages
Line/Module
Redundancy Mode
Shelf
Status
ISiCL “STATUS?” Error Message/Description
Backup
ALERT
SWITCHED TO BACKUP COMMON MODULE
The backup module has detected a failure of the primary module and is now
the active common module.
Primary, Backup
ALERT
SWITCHED TO BACKUP LINE
The backup line was judged to be “better” than the primary line given the
user-defined line criteria, and the backup is now the active line.
Primary, Backup
ALERT
PRIMARY LINE FAILURE
The primary line has met the user-defined criteria for failure.
Primary, Backup
ALERT
BACKUP LINE FAILURE
The backup line has met the user-defined criteria for failure.
Backup
ALERT
PRIMARY MODULE FAILURE
The backup module has detected a failure of the primary module.
Primary
ALERT
BACKUP MODULE FAILURE
The primary module has detected a failure of the backup module.
Primary, Backup
NORMAL
MANUAL SWITCH
Manually generated module or line switch-over.
Primary, Backup
ALARM
RECEIVE BER EXCEEDS USER SETTING
The measured line BER exceeds the user-defined threshold for line failure.
Note:
The next status condition can only be generated if this condition is true:
ESF (Extended Superframe) Framing
Primary, Backup
ALARM
RECEIVE UNAVAILABLE SECOND (UAS)
T1 service in unavailable state (UAS)
Note: In FTI mode, this message is generated if the T1 line is in a UAS state.
In non-FTI mode, this message is generated if the T1 line is in a UAS state
and UAS is enabled as a line switch criterion.
Summary of Contents for ACS-163
Page 4: ...This page is left blank intentionally...
Page 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...