ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation
5 – Remote Control
Version 2.11, August 2011
5-4
Harris Corporation
Intraplex Products
Note:
Pressing up once on the SET/NEXT switch causes the green (top) light to blink, indicating a
change is about to be made. At this point, you can abort the change by pressing down on the
SET/NEXT switch. Pressing up on the SET/NEXT switch a second time actually makes the
change. The green (top) light now stays on and the red light turns off, indicating that the
displayed number is the currently set address.
Table 5-1. Change Multiplexer Network Address From 0001 To 0040
Step
Action
Function
Display
On/Off
Light
1
Press up or down on the GROUP switch one or more times to reach the ADDR group.
ADDR
2
Press down on the SET/NEXT switch once to display the current address. The green
(top) light turns on, indicating the number on the display is the currently set
address.
0001
3
Press down again on the SET/NEXT switch to begin address editing.
0001
4
Press down twice more on the SET/NEXT switch to move the underscore to the third
digit.
0001
5
Press up three times on the SET/NEXT switch to change the third digit from 0 to 4.
0041
6
Press down on the SET/NEXT switch to move the underscore to the last digit.
0041
7
Press up nine times on the SET/NEXT switch to change the last digit from 1 to 0.
0040
8
Press down on the SET/NEXT switch to restore the full size display. The red (bottom)
light turns on, indicating this number is not the current address.
0040
9
Press up twice on the SET/NEXT switch to change the current address to match the
display. After the second press, the green (top) light turns on and the red (bottom)
light turns off, indicating the display shows the current address.
0040
5.1.1.2 Remote Port Parameters (SIO Group) Setting
The ACS-160 Series remote port is an RS-232 compatible serial interface. Table A-2 summarizes the
Serial Input/Output (SIO) group functions. The group contains settings for three parameters:
●
Remote port baud rate (110; 300; 1200; 2400; 4800; 9600; 19,200; or 57,600 bps)
●
Parity mode (mark; space; even; or odd)
●
Remote access lock (locked or unlocked) – Can be used to unlock the remote port locally if the
remote access password is lost
Note:
The remote port always operates using seven data bits, one parity bit, and one stop bit. You
cannot change these parameters.
5.1.1.3 SIO Group Selection
To select the SIO group, press up or down on the GROUP switch one or more times until SIO appears
in the display. At this point, each downward press on the SET/NEXT switch displays the next SIO
function (Table 5-2). The three functions in the SIO group are
●
BAUD
●
PAR
●
Lock
Summary of Contents for ACS-163
Page 4: ...This page is left blank intentionally...
Page 52: ...No header 2 30 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 144: ...No header 5 46 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 166: ...No header 6 22 Harris Corporation Intraplex Products This page is left blank intentionally...
Page 172: ...No header 7 6 Harris Corporation Intraplex Products This page is left blank intentionally...