Physical installation
17
Physical installation
Installation safety
Warning! Read the Safety Information section at the beginning of this manual before connecting the
fixture to AC mains power.
Powerful light can damage the control panel display. Do not point the output from other lighting
fixtures at the MAC Aura XIP.
To avoid head collisions when installing MAC Aura XIP fixtures beside each other, allow a minimum
center-to-center distance between fixtures of 350 mm (13.8 in.). The fixture also contains a
programmable pan/tilt limitation system that can be used to limit head movement in order to prevent
head collisions. See the MAC Aura XIP User Guide for details.
See Figure 1. The MAC Aura XIP’s lens can focus sunlight and strong artificial light, creating a
potential fire hazard and causing damage that is not covered by the product warranty. Position or
shade the head so that the front lens will not be exposed to sunlight or another strong light source
from any angle – even for a few seconds.
The fixture weighs 8.9 kg (19.7 lbs.), not including installation hardware. See “Dimensions” on page 2 for
details of the fixture’s physical dimensions.
Installation hardware
Two omega brackets are supplied with the fixture. Martin can supply as accessories suitable rigging clamps
and safety cables that are approved for the weight of the fixture. Contact your Martin supplier for details.
Figure 1: Potential sunlight damage
Safety cable,
60 kg SWL,
black = P/N 91604006
Figure 2: Martin rigging hardware
Half-coupler
Omega bracket for
rigging clamp,
rigging clamp attachment
P/N 91602005
silver = P/N 91604007