Error messages
Error messages indicate that a problem is present. The MAC Aura XIP communicates errors as follows:
• Error messages flash in the display.
• If more than one error is detected, the fixture flashes all errors three times each.
• Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
• If an error is present, the status LED flashes red.
The possible error messages are listed in Table 6 below:
UITW*
UI TEMP HIGH
User interface (LCD display and control panel) PCB sensor detects
abnormally high operating temperature.*
WTTL
WET TOO LONG
Fixture has been wet for an extended period. To remove the
warning, a complete dry-off procedure is required, especially before
storing/transporting the fixture or re-using it in wet conditions. To dry
off the fixture, move it to a dry location, wipe it with a cloth to remove
pooled water and then activate the DRY OFF program in the
SERVICE menu. Check that the fixture is completely dry before
storing it.
Short code
Long message
Explanation
ACER
AURA CALIB ERROR
Aura calibration data not found.
BCER
BEAM CALIB ERROR
Beam calibration data not found.
BETC
BEAM TMP CUTOFF
Beam PCB temperature cutoff activated.
BETE
BEAM TMP SEN ERR
Beam PCB temperature sensor error.
CELD
COM ERR LED DRV
LED driver communication error.
CEPN
COM ERR PAN
Pan communication failure.
COLD
FIXTURE COLD
Fixture too cold. Physical movement of effects is disabled until
fixture has warmed up.
FAN
BASE FAN ERR
Base cooling fan error.
FAN
HEAD FAN ERR
Head cooling fan error.
FAN
YOKE FAN ERR
Yoke cooling fan error.
FBEP
PAN FBACK ERR
Pan position magnetic indexing system timeout. Fixture is unable to
correct pan position (but pan movement will often still be possible).
FBET
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to
correct tilt position (but tilt movement will often still be possible).
MMER
MISSING MODULE ERR
Impossible to communicate with a module that should be present.
Module missing or not correctly connected.
PAER
PAN ERROR
Pan position electrical indexing system timeout.
PFTC
PFC TEMP CUTOFF
Power factor correction system temperature cutoff activated.
PFTE
PFC TEMP SEN ERR
Power factor correction system temperature sensor error.
PSER
PAN TEMP SEN ERR
Pan motor temperature sensor error.
PTCM
P/T SENSOR ADJUST
Pan/tilt sensors are incorrectly adjusted.
PTTC
PT TEMP CUTOFF
Pan/tilt PCB temperature cutoff activated.
PTTE
PT TEMP SEN ERR
Pan/tilt PCB temperature sensor error.
SEER
ARTNET SOURCES EXCEED
Number of Art-Net control sources exceeded.
Table 6: Error messages