HI 1746-WS WEIGH SCALE MODULE
4-10
Executable Command
List
CAUTION:
ALWAYS PERFORM A READ COMMAND
FIRST BEFORE THE WRITE COMMAND
EVERYTIME, TO GET THE CORRECT
SEQUENCE NUMBER. (SEE THE SET-
PARAMS EXAMPLE, RUNG 0 FOR THE LAD-
DER LOGIC)
Zero Command
(ZEROCMD)
The Zero Command requests that the current gross
weight be set to zero.
Error Return Values:
•
NOTALLOWED - the ZeroEnable parameter is
not set to TRUE (1),
•
OUTOFTOLERANCE - the current weight value
is beyond the limits set by the zero tolerance
parameter.
•
“STATUSWORD” - the command failed because
the weight was not stable (in motion), or that
there was an A/D error of some kind.
SEQ
NUMBER
0
COMMAND#
(Hex)
1
STATUS
2
OFFSET
3
LENGTH
4
DATA
5-16
From M1 File
1
Tare Command
(TARECMD)
The Tare Command requests the current net weight be
set to zero.
Summary of Contents for C Series
Page 8: ...HI 1746 WS WEIGHT SCALE MODULE vi...
Page 10: ...HI 1746 WS WEIGH SCALE MODULE II...
Page 46: ...HI 1746 WS WEIGH SCALE MODULE 4 16 I O Setup Ladder Logic for Remote Mode Operation...
Page 47: ...Chapter 4 Setup 4 17...
Page 54: ...HI 1746 WS WEIGH SCALE MODULE 4 24 SETPARAMS Remote Mode of Operation...
Page 55: ...Chapter 4 Setup 4 25...
Page 56: ...HI 1746 WS WEIGH SCALE MODULE 4 26...
Page 60: ...HI 1746 WS WEIGH SCALE MODULE 4 30...
Page 69: ...Chapter 5 Calibration 5 9...
Page 70: ...HI 1746 WS WEIGH SCALE MODULE 5 10 FIG 5 5 C2 LADDER LOGIC EXAMPLE LOCAL MODE OF OPERATION...
Page 74: ...HI 1746 WS WEIGH SCALE MODULE 5 14...
Page 84: ...HI 1746 WS WEIGH SCALE MODULE 6 10...
Page 92: ...HI 1756 WS MANUAL...