HI 1746-WS WEIGH SCALE MODULE
2-2
Common-Mode
Rejection
110dB at or below 60 Hz
Common-Mode
Voltage Range
2.5VDC maximum (with respect to earth ground)
Backplane Input
Voltage
5 VDC maximum (with respect to earth ground)
Backplane Current
Load
0.250 Amps at 5 VDC
Power
+5 VDC +/- 5%
C2 Calibration
Input
Isolation from digital section 1000 VDC minimum.
Cable lengths
1000 feet maximum of C2 authorized cable
250 feet maximum of C2 authorized cable (Maximum
of 4 load sensors) with IT Junction box.
Load Cell
Excitation
5 VDC +/- 1.15 W maximum.
Isolation from digital section 1000 VDC minimum
C2 Calibration
Output
Isolation from digital section 1000 VDC minimum
Set Point (1 & 2)
Out
Discrete outputs (TTL) step function of 0 or +5 VDC
to drive an SSR
Environmental
Requirements
Temperature
Coefficient
Less than 0.005% of full scale per degree C for Cal-
LO and Cal-HI reference points
Operating
Temperature
Range
0
o
C to 60
o
C (32
o
F to 140
o
F)
Storage
Temperature
Range
-20
o
C to 85
o
C (-4
o
F to 185
o
F)
Humidity Range
0-90% (non-condensing)
Summary of Contents for C Series
Page 8: ...HI 1746 WS WEIGHT SCALE MODULE vi...
Page 10: ...HI 1746 WS WEIGH SCALE MODULE II...
Page 46: ...HI 1746 WS WEIGH SCALE MODULE 4 16 I O Setup Ladder Logic for Remote Mode Operation...
Page 47: ...Chapter 4 Setup 4 17...
Page 54: ...HI 1746 WS WEIGH SCALE MODULE 4 24 SETPARAMS Remote Mode of Operation...
Page 55: ...Chapter 4 Setup 4 25...
Page 56: ...HI 1746 WS WEIGH SCALE MODULE 4 26...
Page 60: ...HI 1746 WS WEIGH SCALE MODULE 4 30...
Page 69: ...Chapter 5 Calibration 5 9...
Page 70: ...HI 1746 WS WEIGH SCALE MODULE 5 10 FIG 5 5 C2 LADDER LOGIC EXAMPLE LOCAL MODE OF OPERATION...
Page 74: ...HI 1746 WS WEIGH SCALE MODULE 5 14...
Page 84: ...HI 1746 WS WEIGH SCALE MODULE 6 10...
Page 92: ...HI 1756 WS MANUAL...