5 - Operation
67
TurboFiller Rinsing
÷
NOTE! It is important to suck from the rising tank or an external
tank with clean water.
Rinse the TurboFiller and chemical containers as follows:
Cleaning empty containers - TurboFiller lid is open
1.
Put container over the rotating flushing nozzle in the middle of the
TurboFiller, so that the nozzle is inside the container.
2.
Simultaneously press the Chemical Container Cleaning lever and
the TurboFiller suction valve. This rinses the chemical container
with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
TurboFiller rinsing - TurboFiller lid is closed
1.
Close TurboFiller lid.
2.
Turn the suction SmartValve towards “Rinsing tank” or “External Filling Device”, if clean water is available here.
3.
Open the Turbo Deflector Valve
for 1 minute to get plenty of clean water through the hoses.
4.
Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the hopper
with the flushing nozzle, while the rinsing liquid is emptied out of the TurboFiller.
5.
Rinse the hopper for 30-40 seconds.
6.
Open the lid to inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve, until
the TurboFiller is empty.
7.
After the last flushing, the TurboFiller suction valve must be open for at least 20 seconds, after the rinse water is no
longer visible in the hopper, in order to completely empty the transfer hoses into the main tank.
μ
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying. This is to ensure that it is clean,
before spraying other crops that may be sensitive to the chemicals just used. See section “Cleaning” on page 69 for
details.
BoomPrime (optional)
The BoomPrime system works automatically, and it is activated, when a spray job is prepared:
1.
Unfold the boom and turn on the PTO.
2.
Set pressure SmartValve to “Spraying”, suction valve to “Main tank”
and agitation valve to “Agitation”, if needed.
3.
Adjust the spray pressure to what will be used when spraying.
4.
The boom will then be fully primed within 1-2 minutes.
If the nozzles start to leak, when closing one or more sections during a
spray job, proceed as follows:
1.
Adjust the pressure on the BoomPrime pressure regulation.
2.
Turn Pressure SmartValve to “Main tank”.
3.
Disconnect the PTO.
If adjustment of the BoomPrime system might be necessary, please refer to “BoomPrime Adjustment (optional)” on page 48.
Summary of Contents for NAVIGATOR FORCE
Page 4: ...1 EU Declaration 4 ...
Page 12: ...2 Safety Notes 12 ...
Page 54: ...4 Sprayer setup 54 ...
Page 76: ...6 Maintenance 76 Boom lubrication oiling plan ...
Page 112: ...8 Technical specifications 112 ...
Page 116: ...Index 116 ...
Page 118: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 Nørre Alslev DENMARK ...