IntelliTrack Front Potentiometer Calibration
If the IntelliTrack front potentiometer on the drawbar can not be mounted correctly (with the bar not perpendicular to
drawbar), then the following must be done.
1.
Align the drawbar by measuring the blank part of the hydraulic cylinder pistons. The sprayer’s drawbar is aligned, when
the two cylinder pistons have the same length, plus/minus 2 mm. Adjust with manual track button on the controller.
2.
Place the transverse potentiometer bar absolutely perpendicular to the drawbar.
3.
Go to menu 4.7 in the controller, and check if the potentiometer reading F is 2.50 Volt.
4.
Adjust the potentiometer housing, until the controller reads 2.50 Volt.
5.
Tighten the potentiometer body screws again.
€
DANGER! Be careful when operating the steering! Make sure that there is space enough to steer the sprayer from side
to side! Only persons working on the sprayer is allowed in the moving area of the sprayer!