4 - System setup
4.106
The Rate Control Settings screen appears.
1.
Press
to open File Selection screen.
2.
The File Selection screen appears. Highlight
your desired .shp file and press
.
÷
NOTE! Select the product and units that the
shape file prescription was made for.
3.
Select Data From Shape File
Select the column that contains the product
recommendation rate. The list on the right
side of the dialogue shows sample data from
the selected column.
4.
Select Units
Select the controlling units for product
application.
5.
Default Rate Setting
The system assigns a default rate. Use the on-
screen keypad to edit the value if desired.
±
WARNING! Selection of the wrong data
column or unit will result in misapplication
of product.
÷
NOTE! The only time the default rate is used
by the system during product application is if the Rate Outside of Field selection is set to "Rx default". This setting is
located in the equipment configuration settings portion of configuration setup. If the Rate Outside of Field selection
is set to "Rx default", the default target rate will be used when the vehicle exits the area covered in the prescription
map.
Rate Control Settings
ExTran
Full:
Current:
Rate 1:
Rate 2:
Increment:
Prescription:
Minimum Flow:
File Selection
Name
Autopilot_dry.irx
demo_2_liquid.irx
demo_2_liquid_3_dry.irx
demo_3_liquid.irx
demo_3dry_1liq.irx
Demo Field
Planting
Application
Field:
Product 1:
Product 2:
Product 3:
Product 4:
Product 5:
Summary of Contents for HC 8500
Page 2: ......
Page 4: ......
Page 8: ...Table of contents TOC 4 ...
Page 10: ...1 Welcome 1 2 ...
Page 12: ...2 Safety Notes 2 2 ...
Page 26: ...3 Description 3 14 ...
Page 164: ...6 Maintenance 6 2 ...
Page 176: ...7 Fault finding 7 12 ...
Page 180: ...8 Technical specifications 8 4 ...
Page 183: ......