![Happy HCS-1201-30 Maintenance Manual Download Page 68](http://html1.mh-extra.com/html/happy/hcs-1201-30/hcs-1201-30_maintenance-manual_595750068.webp)
68/204
Adjustment of needle height
3-3-6
7. Put needle height gauge in rotary hook.
8. Adjust the needle bar height up and down till the needle tip
touches to the gauge slightly.
9. Set direction of needle stop as illustrated below.
About 30 degrees
* Check needle holder dose not touch to Needle guard.
10. Tighten the screw of needle bar boss.
11. Tighten the screw of needle bar boss B.
When tightening needle bar boss B, please insert gauge
[
25mm
] in-between.
* Check the movement of needle bar goes smoothly.
12. Put things back in reverse order of 1-5 to finish.
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...