Adjustment of pressure foot bracket ass’y
3-2-17
1. Fix pressure foot bracket ass’y tentatively.
2. Lift up pressure foot.
3. Adjust the position of the pressure foot bracket ass’y.
<Important>
The space between needle plate and pressure foot
should be [
24.0 - 24.3mm
].
Gauge for adjustment of height of pressure foot bracket
4. Adjust position of pressure foot guide plate B ass’y.
<Caution>
Make sure that pressure foot guide plate B ass’y is mount
perpendicular and parallel to the body.
5. Procedure is done after confirming the pressure foot
movement by pressing the P_FOOT key on control box.
90 degrees
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...