123/204
Exchange of motor belt
3-8-4
7. Remove drive pulley and motor belt.
Install good motor belt.
8. Install each parts in reverse order.
For installation and adjustment of each part,
please refer to respective manuals.
Referring to [3-8-3 Adjustment of motor belt tension],
adjust tensile strength of motor belt.
<Important>
Pay attention to following (1) - (4).
(1)When you install upper shaft collar, upper pulley,
drive pulley and crank, please fix them on flat surface
of upper shaft with screw.
(2)Make sure that pulleys and collars are attached without
space from machine body except upper pulley.
(3)Position of upper pulley is [
2mm
] from upper shaft collar.
Upper pulley positioning gauge [
2mm
]
(4)Confirm that belt is not interfere the pulley flange and
not come out from pulley groove.
Adjustment will be done with following pulley.
Timing belt has to be adjusted with [upper pulley position].
Motor belt has to be adjusted with [motor pulley position].
9. Check and adjust following timing to finish.
(1)Upper shaft timing(L point, C point).
(2)Take-up lever timing.
(3)Rotary hook timing.
(4)Thread cut timing.
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...