187/204
Trouble shooting(Off-registration of pattern)
7-2-4
Trouble Factor Cause of trouble and measure
Page
Off-registration Operator 2. Is cloth properly stretched.
(6-2) (7-5)
of pattern 2-1 Stretch properly.
3. Is thread tension proper?
(4-5) (8-1)
3-1 Observing sewing rhythm, set thread tension properly.
4. Was the machine left for a long time in middle of sewing?
4-1 Try to finish sewing as soon as possible.
Environment
1. Is strength of table and floor enough?
(2-4)
1-1 Check where to place the machine again.
1-2 Move to where floor is strong enough.
1-3 Use strong table to be able to endure vibration.
2. No problem in pulse motor driver by low power and voltage (variation)?
2-1 Supply rated voltage.
2-2 Use transformer.
2-3 Use stabilizer.
3. Is there no place where noise is generated near the machine?
3-1 Don't use the machine near where noise is generated.
4. Doesn't drive frame hit obstacle?
(2-4)
4-1 Remove obstacle.
4-2 When useing cap frame, see not to hit table.
(2-5)
Thread & 1. Not using shrinkable cloth?
(4-3)
cloth 1-1 Use backing paper (consider number of sheets to use).
2. Isn't breakable cloth is used by thread tightening?
(4-3)
2-1 Use backing paper (consider number of sheets to use).
3. Is proper backing paper used?
(4-3)
3-1 Use backing paper to match cloth.
4. Isn't cloth (embroidery) too heavy?
4-1 Don't use extremely heavy cloth.
Pattern
1. Pattern data may be destroyed.
(5-4) (5-6)
1-1 Read again.
1-2 Let new pattern read.
2. Memory pattern was destroyed.
(5-4) (5-6)
2-1 Let new pattern read.
3. No problem in floppy disc or memory card?
3-1 Initialize and read again.
3-2 Prepare new floppy disc or memory card.
( ) ----- Reference instruction book
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...