197/204
Trouble shooting(
Others / Electric
)
7-2-12
Trouble Factor Cause of trouble and measure
Page
Frame overrun
Mechanical
1. Interference between censor circuit board and douser.
1-1 Position adjustment of douser.
1-2 Replace of censor circuit board.
2. Check whether cable has problem or not.
2-1 Replace in case damage exists.
2-2 Insert connector again.
3. Check CPU board.
3-1 Replace of CPU circuit board
Key on control box
Mechanical
1. When removing panel in replacing circuit board , due to poor cable bundling,
can not be pressed
circuit board being pushed from inside.
down and returned
1-1 Bundle cable again
Defect of LCD
Mechanical
1. Check LCD .
1-1 Replace of LCD
2. Inadequate condition of cable insertion
2-1 Insert to the back firmly
3. Check whether CPU board is out of order or not.
3-1 Replace of CPU board
Defect of data
Mechanical
1. Check whether cable is insert firmly between CPU Board and serial board or not.
communication
1-1 Insert again
(E-90)
2. Check whether PC has problem or not.
(E-91)
2-1 Affirm whether there is problem or not.
3. Check serial circuit board is out of order or not.
3-1 Replace of serial circuit board.
4. Check whether CPU circuit board is out of order or not.
4-1 Replace of CPU board.
Operator 1. Baud rate does not fit between machine side and PC side.
1-1 Make setting of baud rate
(5-2)
P19-P20
Pattern disappears
Mechanical
1. Trouble in back-up battery
/ Watch doesn't
1-1 Replace battery on CPU board.
4-1-2
indicate time 2. No trouble in memory tip on CPU board?
2-1 Conduct [memory all clear] in maintenance mode.
5-5-3
2-2 If above measure doesn't solve the trouble, replace CPU circuit board.
( ) ----- Reference instruction book
P**-P** --- Refer to Happy Link instruction book
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...