195/204
Trouble shooting(Defect on Thread catcher)
7-2-10
Trouble Factor Cause of trouble and measure
Page
does not catch
Mechanical
1. Thead catcher does not extend hook sufficiently.
thread 1-1 Adjust position of Thread catcher .
1-2 Adjust position of Thread holder.
2. Excessive distance between Hook and tip of Needle.
2-1 Adjust position of Thread catcher.
2-2 Adjust position of Thread holder.
Hook of Thread
Mechanical
1. Check Hook of Thread catcher bent or not.
catcher does not
1-1 Repair bent Hook.
extend
1-2 Replace Hook.
2. Check position of Thread catcher is proper.
2-1 Adjust
3. Check position of Thread holder is proper.
3-1 Adjust
4. Check Thread catcher.
4-1 Check cable is securely connected.
4-2 Replace Pulse Motor with trouble.
5. Check CPU Board.
5-1 Replace CPU Board.
Hook hits or
Mechanical
1. Check Hook is bent or not.
catches Needle
1-1 Repair bent Hook.
(E-193)
1-2 Replace Hook.
2. Check position of Thread catcher is proper.
2-1 Adjust
3. Check position of Thread holder is proper.
3-1 Adjust
Operator 1. Check if Needle is securely set.
1-1 Set Needle properly.
(4-1)
3-1-2
Constant display
Mechanical
1. Trouble of Photo sensor.
of E-193
1-1 Replace Photo sensor.
( ) ----- Reference instruction book
Summary of Contents for HCS-1201-30
Page 12: ...12 204 2 Outer covers 2 1 Removal of outer covers ...
Page 81: ...81 204 3 4 Needle bar change unit 3 4 1 Fixing of needle bar change unit ...
Page 124: ...124 204 4 Electricity 4 1 Circuit board related parts 4 2 Sensors ...
Page 153: ...153 204 5 4 Revolution 5 4 1 Adjustment of revolution ...
Page 164: ...164 204 5 7 Detection of power outage 5 7 1 Adjustment of power outage detection ...
Page 168: ...168 204 Electrical connection diagram 6 1 1 ...
Page 169: ...169 204 List of electrical connection diagrams 6 1 2 ...
Page 170: ...170 204 6 2 Reference diagram for wiring 6 2 1 Reference diagram for wiring AC Iine ...
Page 171: ...171 204 Reference diagram for wiring AC Iine 6 2 1 ...
Page 173: ...173 204 VFNC1 S Connection of inverter and setting of parameter 6 3 1 ...
Page 174: ...174 204 FR S510W Connection of inverter and setting of parameter 6 3 2 ...
Page 198: ...198 204 7 3 Error 7 3 1 Error and measure ...
Page 202: ...202 204 7 4 Reference date 7 4 1 Tables for timing adjustment value ...