sTÖRunGen unD ABhILfe
e
nglish
TRouBLe shooTInG
Type of Malfunction / Cause
Possible Cause
Possible Clearance
•
Air system does not function
•
Check you have an electricity supply?
−
Malfunction in electrical mains
−
Are the plug connections to the
control correctly seated?
•
Control does not react
•
Control defective
•
Control element defective
•
Blower defective
−
Call electrician
−
Pull and reinsert plug
•
Reconfigure Poolmaster
•
Replace control
•
Replace control element
•
Replace blower
•
Hydro system function insufficient
•
Hydro system does not function
•
Filter at intake socket is blocked
•
Nozzle dirty
•
Is voltage applied?
−
Malfunction in electrical mains
−
Are the plug connections to the
control correctly seated?
•
Is the water level high enough?
•
Water level sensor does not react
•
Control does not react
•
Control defective
•
Control element defective
•
Hydraulic pump defective
•
Remove cover at intake socket and
clean filter (see service)
•
Clean nozzle (see service)
−
Call electrician
−
Pull and reinsert plug
•
Continue to fill tub
•
Adjust sensor
•
Replace sensor
•
Reconfigure Poolmaster
•
Replace control
•
Replace control element
•
Replace hydraulic pump
•
System switches itself on without an
obvious reason
•
Automatic cleaning function of the air
nozzles
•
Has the room temperature changed
(e.g. floor heating underneath the
whirlpool)
•
Has the humidity in the room changed
(e.g. use of a shower in the same room)
•
Were cables, water pipes or other
electrically conductive materials laid in
the area of the water level sensor?
•
Is/was cleaning work performed near
the tub? (e.g. moist cleaning cloth near
the water level sensors)
•
Okay
•
Readjust sensitivity of the water level
sensor
•
Readjust sensitivity of the water level
sensor
•
Reposition cables, water pipes or similar
•
Remove objects from the tub
•
Water nozzle
•
Nozzle dirty
•
Nozzle head not adjustable
−
is seized
−
is loose
•
Clean nozzle (see service)
−
Reposition O-ring behind head
−
Replace O-ring behind head
Leakage:
•
air
•
Water underneath the tub
•
Air hose loosened on:
−
Blower
−
Air distributor
−
Air nozzle
•
Hydro hose loose on:
−
Pump
−
Hydro nozzles
•
Drain/overflow defective?
•
Seals on nozzles leaking?
•
Acrylic material damaged?
•
Tub inflow connection leaking?
•
Tighten hose clamp / disconnect and
reconnect hose
•
Retighten hose clamp
•
Replace seals
•
Replace seals
•
Repair acrylic material with repair sets
•
Replace seals
•
Underwater lighting does not switch on
•
Is the water level high enough?
•
Lighting element defective?
•
Is voltage applied?
−
Malfunction in electrical mains
−
Are the plug connections to the
control correctly seated?
•
Water level sensor does not react
•
Continue to fill tub
•
Replace lighting element
−
Call electrician
−
Pull and reinsert plug
•
Adjust sensor
•
Replace sensor
english
Italiano
RIsoLuzIone DeI PRoBLeMI
Summary of Contents for Pharo 300 Series
Page 33: ...33 Deutsch Ausstattung English Equipment Italiano Equipaggiamento ...
Page 37: ...37 Deutsch English Italiano ...
Page 43: ...43 A B Deutsch Montagebeispiel English Installation example Italiano Esempio di montaggio ...
Page 45: ...45 A 2 1 3 6 4 7 5 B 5 C Deutsch Montage English Installation Italiano Montaggio ...
Page 47: ...47 D 1 2 3 Deutsch Montage English Installation Italiano Montaggio ...
Page 87: ...87 Deutsch English Italiano ...
Page 92: ...92 ...
Page 93: ...93 Deutsch English Italiano ...