RevV4 Valves & Systems Service Manual
40
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
Sanitation Procedure
At the start up or after service, the following procedure is recommended to exclude the possibility of
microbiological contamination of the system. This procedure relates only to the original description of
equipment and options described for this system. Any alterations to the configuration would require
evaluation by a trained water professional.
1.
Remove the brine tank cover and locate the brine well.
2.
Remove the brine well cap.
3.
Pour 1/3 cup of unscented bleach into the brine well.
4.
Place cap back on brine well and cover back on brine tank.
5.
The system must be regenerated. Select an immediate regeneration or a delayed regeneration.
Immediate Regeneration
a.
At the control valve, press and and hold for 3 seconds to unlock the valve.
b.
Press to start an immediate regeneration.
c.
Allow approximately 2 hours for the valve to complete its regeneration cycle and return to service mode.
Delayed Regeneration
a.
At the control valve, press and hold for 3 seconds to set a delayed regeneration that very next
morning at the programmed time. (Default setting is 2:00am)