RevV4 Valves & Systems Service Manual
19
Hankscraft Runxin, LLC 300 Wengel Drive 608.524.9465 hrh2o.com [email protected]
Programming: Modes A-02
Parameter
Unit
Default
Description
Review Company Info
Displays current programmed company information.
Language *
English
Set Company Info *
Set company information for display. Three lines available for input.
Set Time of Day
24-hr. Clock
Set current time of day. 24-hour clock format.
Set Date
Set current month, day, and year. XX/XX/20XX
Set Program Type *
Interlock / Alternate Interlock
Interlock
Used as a stand-alone installation and twin demand in conjunction with No
Hard Water version of the RevV4.
Set Regen Cycles *
1, 2, 3
2
Recommended setting to Sequence 2. See Pages 7-8. Service → Backwash →
Brine & Slow Rinse → Back Wash → Fast Rinse → Brine Refill.
Set Clear Data *
Close/Open Close
Skip during initial set-up. Clears all stored memory and restores default settings.
Close = Data saved Open = Reset data
Set Regen Mode: A-01-A-07 *
A-03
Change to A-02 Meter Immediate.
Set Capacity
Grains
2100
To figure capacity, take the total resin volume multiplied by .75. Divide by grains
hardness of water supply. Ex: 1 Cu/Ft =32,000 x .75 at 15 grains hardness.
(32,000 x .75) ÷ 15=1,600 gal. Enter that value here.
Set Backwash Time
Min.
0
Set to 0 (zero) when using Sequence 2 as a softener install.
Set B.S.R. Time
Min.
60
Brine Slow Rinse Stage of Regeneration.
Set Secondary B.W.T.
(Backwash Time)
Min.
10
Set Fast Rinse Time
Min.
10
Set B.R. Time (Brine Refill)
Min:Sec
10:00
Refill time is calculated based on total resin volume. Note: 1 gal. water dissolves
3 lbs. of salt. See note below for refill time.
Max Days for Regeneration
Days
30
A regeneration is forced every 30 days if no water has been used.
Signal Output Mode b-01 (02) *
b-01
Used for external device. b-01. Disregard for standard installation.
Set Service Alarm *
Days
730
Alarm rings to prompt a service call. Occurs at the number of days set at 8pm
for 2 minutes. Display changes to prompt the homeowner to call their dealer.
Daily Usage Log
Gal.
Shows the gallons used each day for the last 7 days.
Daily Peak Usage
Gal.
Shows the highest gallon usage day for the last 7 days.
Weekly Usage Log
Gal.
Shows the gallons used each week for the last 52 weeks.
Weekly Peak Usage
Gal.
Shows the highest gallon usage week for the last 52 weeks.
Monthly Usage Log
Gal.
Shows the gallons used each month for the last 12 months.
Monthly Peak Usage
Gal.
Shows the highest gallon usage month for the last 12 months.
Review Regen Times
Displays the number of times the valve has regenerated independently.
Review Software Ver.
Shows current software version of RevV4 valve.
Above parameters are located in standard program settings menu. (*) Denotes parameters located in advanced program settings menu.