Regeneration
Mode
A-01 Meter Delay: Regeneration happens when the capacity reaches zero and the preset time of
regeneration is reached.
A-02 Meter Immediate: Regeneration happens when the capacity reaches zero.
A-03 Intelligent Meter Delay: The same delay function as A-01 but the capacity is determined by entering
the total Resin Capacity, Feed Water Hardness, and the Number of People in the household. The control
valve automatically calculates the gallons for regeneration.
A-04 Intelligent Meter Immediate: The same function as A-02 but the capacity is determined by entering
the Total Resin Capacity and Feed Water Hardness. The control valve automatically calculates the gallons
for regeneration.
A-05 Remaining Compare: Compares current usage with previous 365 day daily usage to intelligently
determine when regeneration will occur. Regeneration starts at the set regeneration time.
A-06 By Day (timer): Service days count down to zero (0) and regeneration starts at the set regeneration
time.
A-07 Filter Meter: Filter mode, regeneration occurs when the capacity reaches zero and the preset time
for regeneration is reached.