7.
Data on the Inverter and Diaphragm pump
Specification
▶
After input all the parameters, turn off the system for 10 seconds and on.
N
o
Fixed No.
Description
Set
Data
1
A1-01
Access level
4
2
B1-01
Currency selection
2
3
B1-02
Operating type selection
2
4
B2-02
DC control currency
40
5
B2-04
DC control time for the
stopping
10
6
C1-01
Acceleration time
400
7
C1-02
Deceleration time
600
8
E1-01
Input voltage setting
380
9
E1-04
Max. voltage frequency
160
10
E1-05
Max. voltage
380
11
E2-01
Motor currency
9.34
12
H5-01
Station address
1
13
H5-05
Transfer error detection
selection
0
14
L2-01
Moment power selection
1
15
L3-01
Stall prevention during
acceleration
0
16
L3-04
Stall prevention during
deceleration
0
17
O1-03
Currency order setting
2
[email protected] / [email protected]
ㅣ
10
Summary of Contents for J1250
Page 1: ...Operating Manual J1250 Continuous Tubular Centrifuge...
Page 5: ...2 Appearance Front View Side View Upper View info ihanil com techsupport ihanil com 2...
Page 6: ...3 Structure 3 info ihanil com techsupport ihanil com...
Page 23: ...9 Drag Drag Assembly Drawing Parts info ihanil com techsupport ihanil com 20...
Page 29: ...MEMO...