AI-118 operation manual
issue 1 19.10.07 display version 07 . plc controller version 07
P.17 of 50
Main page - 1 (page introduction)
The page of the panel is named “main” which means it is the main control of the
machine.
1
2
3
4
5
6
7
8
9
10
11
12
Figure 10 Main Page - 1
1. Heating temperature setting button & display
,
press to set temperature, the
setting range is 50-800.
2. When the button changed to red, the nozzle will go to the working position, and
the machine will be locked. After the lock, the machine will not work for safety
protection. This button is used to adjust the position of nozzle.
After the wind
nozzle position is adjusted, you need to lift this button or else the machine cannot
work.
Note: This function can only be used when the temperature is less than
50 °C.
3. Nozzle temperature feedback (real time temperature feedback). It will display “<
50”, when the temperature less than 50
℃
. Make sure the temperature is less
than 50
℃
when you turn off the power supply and compressed air.
4. This data will display if you turn on the “power save” button. If the device is
heating and there is no operation, the countdown is performed here, and the
heater will automatically turn off when the time is up; if there is any operation
during the countdown, the countdown will restart.