STD
S AUX
P AUX
823 008 xxx
D
D
823 034 xxx
D
D
D
Note colour
The Standard AUX has 5 x AUX connectors that can be
configured using DIAG+.
AUX 1 - B+ voltage switched output
AUX 2 - B+ voltage switched output and monitor input
AUX 3 - B+ voltage switched output and monitor input
AUX 4 - analogue input
AUX 5 - analogue input
Programming Standard AUX using DIAG+ V6
The AUX configuration screen shows the various
auxiliary connections that can be used.
AUX 1
AUX 2
red only
AUX 3
red only
AUX 4
AUX 5
Clicking on the drop down arrow displays a list of
options that can be selected on that auxiliary.
Error message: an error message will be displayed if an
auxiliary configuration is created and sent to an ECU
that does not support that function.
Auxiliary operation
Standard AUX (STD)
Connections: 3 o 2 inputs. EB+ includes by default 5 auxiliary ports for various surrounding functions. 3
of these auxiliaries are digital, 2 are analogue inputs. These amount of inputs and outputs are sufficient for most
commonly used standard trailer applications. For example ILAS
®
-E (= lift axle control) and COLAS
®
(= return to
ride height) digital AUX are required, whereas for LWI (= lining wear indicator) and Soft Docking (= ramp approach
system) analogue inputs are needed. In case of malfunction (short circuit / open circuit) the EB+ system generates
a DTC code and the service lamp will be triggered after start up.
Auxiliary functions are dependant on the installed EBS
product.
Summary of Contents for EB+ Gen3
Page 1: ...Innovative Vehicle Solutions INSTALLATION GUIDE Electronic Braking System ...
Page 86: ...EB Gen3 Installation guide 86 Innovative Vehicle Solutions 2013 Wiring diagram Gen3 2M ...
Page 87: ...EB Gen3 Installation guide 87 2013 Innovative Vehicle Solutions Wiring diagram Gen3 3M ...
Page 131: ...EB Gen3 Installation guide 131 2013 Innovative Vehicle Solutions Notes ...