EB+ Gen3
Installation guide
78
Innovative Vehicle Solutions
2013
Blanking
plugs
AUX 1
connection
ECU connectors – sensor & AUX
The ECU is supplied with blanking plugs in positions
indicated. These require to be removed to allow
fitment of additional sensors or permitted ancillary
equipment.
Example - AUX 1 connection
Identify the AUX 1 position on the front face of the
ECU.
Locate the locking tag ‘O’ position.
With a tool ‘P’ having a flat end of Ø3-2 mm insert
and press in locking tab of plug. While depressed pull
out plug from housing.
Identify orientation:
›
Sensor black body connector
›
Auxiliary blue body connector
›
Diagnostic black body connector
Ensure contact pins and seal are kept clean and free
of any contamination prior to installation. Insert fully
home.
ECU
ECU
O
ECU
Ø 3.0
2.0
P
‘Click’