43
(7) Run
Selecting the desired program and tapping
[Run]
will cause the selected program to be shown in
the running programs area of the top screen.
Error checking will be performed at the same time. If an error such as input of a value outside
the range, etc. is found, an error screen will be shown. When the problem has been solved, the
program can be run.
Error screen showing values outside range
Outside range • STEP 1:
X, Y axis start point and end point
• STEP 3:
X axis start point and end point
• STEP 4:
Y axis start point and end point
➞
Settable ranges: X axis: 0 – 400 mm, Y axis: 0 – 300 mm
SP: Start point
EP: End point
Solder point
number
1.
Close the error screen.
2.
Open the Point Edit Screen for the step to be corrected in the program list.
3.
Input proper values in the start point and end point boxes.
4.
When correction has been finished, tap
[Exit]
.
5.
Correct STEP 3 and STEP 4 in the same way.
6.
After all problems have been corrected, tap
[Update]
in the Program Edit Screen.
After that, tap
[Run]
.
For details on the Point Edit Screen, refer to Point Edit Screen on the next page.
Procedure for Correcting Errors
405.063
405.063
-4.935
-4.935
166.131
166.131
44.263
44.263