21
5-2-2
Attaching the Soldering Iron Unit
1.
Attach the tension springs included with the
soldering unit mount (CX5004) to the soldering
unit mount.
2.
Assemble the soldering unit mount (CX5004)
using 1 of the hexagon socket head cap screws
included with the soldering unit mount.
3.
Attach the soldering unit mount (CX5004)
to the soldering unit fixture base (CX5002)
using 4 of the hexagon socket head cap
screws included with the soldering unit
mount.
The mounting angle can be set with the
soldering unit mount.
For details, refer to “About the Soldering
Unit Mount (CX5004)” (p. 22).
Hexagon socket
head cap screw
M3×10
Hexagon socket
head cap screw
M3×10 (4)
Tension spring (2)