Operation
80
TOPlift L+ edition • Operating instructions • Betriebsanleitung
Stop automatic travel at
intermediate
platform
Fig. 87: Stop at intermediate platform
1
Sticker with position marking
2
Railing brace
The service lift can be stopped manually with the emergency stop button on any
intermediate platform for loading and unloading.
To be able to open the shutter door and the railing door, the cabin must be
stopped exactly in the intended position at platform level.
A sticker with markings (1) on the cabin indicates the necessary positioning.
1.
►
Press the emergency stop button as soon as the mark (1) is exactly at
the level of the upper railing brace (2).
2.
►
Pull out the emergency stop button again if the service lift is to be
restarted, as otherwise starting is prevented.
16.2.5
Display (optional)
Fig. 88: Display
The switch cabinet can be optionally equipped with a display. It indicates faults
and the position of the limit switches.
Display symbol Meaning
Overload / Temperature:
Lights up red if the motor is overloaded or the temperature is too high.
Fall arrester:
Lights up red when the fall arrester has been activated.
CCV temperature too low:
Lights up red if the temperature at the fall arrester is too low.
Shutter door:
The shutter door lights up red when it is open.
The lock lights up red when the shutter door is unlocked.
Shutter door:
The shutter door lights up green when it is closed.
The lock lights up red when the shutter door is unlocked.