18
Operation
Pressing a 8th time, the minute position and “OFF” are
flashing;
Pressing a 9th time, cancel the setting.
(3) Relation to other buttons when timer is set.
Press the
key or
key to exit the current setting,
press them again to operate the function accordingly; Press
the
(ON/OFF) key can exit the timer setting and power
ON/OFF directly. If there is a timer before, the wired controller
will operate by following the previous setting. If not, the wired
controller will have no timer operation.
(1) If Sw5 is on, only the Up/Down swing will be involved in
function circulation. At this time SW7 is invalid.
(2) If Sw5 is off, swing type can be set by Sw7, when Sw7 is
off, only Up/Down swing valid, when Sw7 turns on, Up/Down
and Left/ Right swing valid. Only Up/Down swing is default.
①
If Sw7 is off (default): only Up/Down swing is available.
Press SET key to enter function circulation, Up/Down swing
icon flashing, then press SET key again to confirm with swing
icon statically displaying. If swing function is set, execute the
above operation to cancel.
Swing
Summary of Contents for YR-E17
Page 2: ...1 Interface Display Parts and Functions ...
Page 50: ...49 C C A CON1 B 3 2 1 B red yellow white A Wired Controller Wiring Instruction ...
Page 51: ......
Page 52: ......