Checking the evaporator
- Clean the evaporator at regular intervals using a soft-haired brush.
- If they are bent. Carefully realign the evaporator using a suitable comb.
- Because the evaporator fins is very sharp. Risk of injury on your finger.
- Do not damage the fins. Avoid affecting the performance.
Checking the condensates discharge pipe
- Check the pipe cleanliness
- An obstruction by dust may cause poor condensates flow or even a risk
accumulation of water in the heat pump plastic base.
Checking the Magnesium rod
- The magnesium anode should be replaced in time, avoid tank corrosion.
- Checking magnesium anode once every 2 years .In poor water areas need to shorten
the time.
Drain the water tank to empty
Cut off power supply and shut down water inlet valve, then drain the water tank to
empty via the sewage outlet. Please stay away from the sewage outlet if there is hot
water inside the water tank to avoid injury.