Page 51
ENABLE EMERGENCY KEYS
This enables or disables the functionality of the emergency keys on the console keypad. Factory default is enabled. Select the 1
(YES) key to enable the emergency keys. Select the 2 (NO) key to disable the emergency keys.
ENABLE EMERG KEYS: 1
0=NO 1=YES
TIME DISPLAY
This allows you to choose between AM/PM and 24-HOUR time format.
TIME DISPLAY: 1
1=AM/PM 2=24HR
DATE DISPLAY
This allows you to choose between MONTH/DAY and DAY/MONTH date format.
DATE DISPLAY: 1
1=MMDD 2=DDMM
AC POWER FREQUENCY
Set this to the appropriate AC Powerline Frequency.
AC POWER FREQUENCY: 1
1=60HZ 2=50HZ
DEAD LINE DETECT
NOTE: To disable Omni IIe from detecting a dead line, set this item to '0'; otherwise adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line goes dead.
DEAD LINE DETECT: 8
0-15 0=DISABLE
OFF HOOK DETECT
NOTE: Adjust only under direction of HAI.
This item adjusts the threshold that is used to determine when the phone line is going off hook.
OFF HOOK DETECT: 69
20-250
PICKUP AFTER HANGUP
This item is used to disable Omni IIe from picking up the phone line after the called party hangs up the line.
PICKUP AFTER HANGUP: 1
0=NO 1=YES
Currently, after the called party or the called party's answering machine hangs up the phone line, Omni IIe picks up the line and
make its "Beep". If you wish to turn the Pickup After Hangup OFF, press 0 then ' # '. To turn it back On, press 1 then ' # '.
The default setting for Pickup After Hangup is Yes.
CLOCK ADJUSTMENT
If the clock on an Omni IIe is running faster or slower than the actual time, you can have the Omni IIe automatically compensate
up to 29 seconds per day. The Omni IIe will add or subtract the selected amount of time daily.