Page 48
TYPE NUMBER
DESCRIPTION
AUTO HEAT/COOL
1
Automatic changeover heat and cool thermostat
HEAT/COOL
2
Manual changeover heat and cool thermostat
HEAT
ONLY
3 Heating
only
thermostat
COOL
ONLY
4 Cooling
only
thermostat
SETPOINT
ONLY 5 Setpoint
only
thermostat
Z-WAVE THERMOSTAT NODE ID
If Z-Wave Thermostats are part of the system, the Node ID for the thermostat must be associated (mapped) with the specified
thermostat address in the Omni IIe controller.
TSTAT 1 NODE ID: 0
0-232
THROUGH
TSTAT 4 NODE ID: 0
0-232
↑
Enter the Node ID (0-232) for each Z-Wave thermostat followed by the ' # ' key.
Enter 0 if there is no node associated to the specified thermostat.
SETUP MISCELLANEOUS
To configure the miscellaneous Installer Setup items, from the Installer Setup menu, press the 6 (MISC) key.
INSTALLER CODE
The Installer code allows the installer access to the Installer Setup menu. The Installer code should be changed and not given to
the customer. The Installer code cannot be used for remote phone access.
INSTALLER
CODE:
0000-9999
0000=DISABLE
↓
The default setting for the Installer code is 1 1 1 1.
NOTE:
Remember this Installer code and do not disable. There is no way to reset or retrieve the code! If the code is forgotten or
disabled, the Omni IIe controller must be sent back to the factory. Call for an RA#.
ENABLE PC ACCESS
This enables or disables the PC ACCESS feature. Factory default is enabled.
ENABLE PC ACCESS: 1
0=NO 1=YES