Page 35
UPB STATUS TIME (STATUS TRACKING):
When using HLC, “Status Tracking” is used to update the status of each HLC device in a room whenever a scene is executed in
that room. For example, the scene “A” button is pushed on a Room Controller in the Living Room. All of the lighting loads in
the Living Room are changed, but the status for the individual lighting loads isn’t updated in Omni IIe until a status request
message is sent to each unit. When “Status Tracking” is enabled, this is done automatically after a scene is executed.
The value set for the UPB Status Time is the amount of seconds that the Omni IIe controller waits before requesting status after a
scene is executed. By default, the time is set to 5 seconds. This gives lighting loads (with varying fade rates) the necessary time
to “settle down” before the status is requested.
UPB STATUS TIME: 5
0-255 SECONDS
Enter 1-255 for 1 to 255 seconds. Enter 0 to disable “Status Tracking”.
Note:
“Status Tracking” must be enabled for Omni IIe to accurately set the LED indicators on Room and House Controllers.
X-10 3-PHASE
This setting is used to select whether the X-10 signal is transmitted only at zero crossing for single phase (120V/240V) electrical
systems or is transmitted at 0, 60, and 120 degrees for three phase electrical systems.
X-10 3-PHASE: 0
0=NO 1=YES
To turn 3-Phase On, press 1 then ' # '. To turn 3-Phase Off, press 0 then ' # '. The burst at 60 and 120 degrees will be eliminated.
The default setting for 3-Phase is No.
OUTPUT TYPES
An output type must be specified for each of the voltage outputs and for the interior and exterior horn outputs. The following
output types are available:
OUTPUT TYPE
NUMBER
DESCRIPTION
GENERAL
PURPOSE
0 General
Purpose
Output
OK
TO
ARM
1
OK
To
Arm
ARMED
2
Armed
PRE-ALM
SNDR 3
Pre-Alarm
Sounder
INT
SNDR
4 Interior
Sounder
INT BURG SNDR
5
Interior Burglary Sounder
INT
FIRE
SNDR
6 Interior
Fire Sounder (3 pulse temporal pattern)
EXT
SNDR
7 Exterior
Sounder
EXT BURG SNDR
8
Exterior Burglary Sounder
EXT FIRE SNDR
9
Exterior Fire Sounder (3 pulse temporal pattern)
BURG
COMM
10
Burglary
Communicator
FIRE
COMM
11
Fire
Communicator
AUX COMM
12
Auxiliary Communicator
SWITCHED POWER
13
Switched Power Output