Page 43
TWO-WAY AUDIO
If a Two-Way Audio Module is being used, this item enables hands free audio communication between your customer's premises
and the central station.
After the transmission of the alarm to the central station, the operator can talk and listen to people and sounds at the premises.
TWO-WAY AUDIO: 0
0=NO 1=YES
If a Two-Way Audio Module is part of the system, select the 1 (YES) key to enable this feature.
REPORT OPEN/CLOSE
The communicator can be setup to send an opening and a closing report by user code. Whenever the system is disarmed the
communicator will send an opening report to the central station. When the system is armed, the communicator will send a closing
report to the central station.
REPORT OPEN/CLOSE: 0
0=NO 1=YES
To enable the communicator to send opening and closing reports to the central station, select the 1 (YES) key.
REPORT BYPASS / RESTORE
This item is used to enable/disable reporting to the central station when a zone is bypassed or restored when using Contact ID.
The communicator can be configured to send bypass/restore signals to the central station when using Contact ID. Whenever a
zone is bypassed, the communicator will send a zone bypassed report to the central station. When a zone is restored, the
communicator will send a zone restored report to the central station.
REPORT BYPASS/REST: 1
0=NO 1=YES
To disable the communicator from sending bypass and restore reports to the central station, select the 0 (NO) key.
AUTOMATIC TEST TIME
The communicator CAN be setup to automatically send a test code to the central station on a periodic basis. AUTOMATIC
TEST TIME is used to set the time and days of the week of the test, and the TEST CODE specifies the code that will be
transmitted for the test.
AUTOMATIC
TEST
TIME:
-- NEVER #=CHNG
To disable the automatic test, press the ' # ' key and then 0 for Never, and ' # '.
TEST CODE: 98
0-FF
ALARM CODES (4/2 and 3/1 Formats)
Press the down arrow (
Ø
) to advance to the next ZONE ALARM CODE. Press the up arrow (
×
) to go to the previous ZONE
ALARM CODE. To change an alarm code, enter two digits for 4/2 format, or one digit when using 3/1 format, then press the ' # '
key.
Enter the 2 digit alarm code (1 digits if using 3/1 format) and press ' # '. To enter the digits B-F, first press the OFF key, then
press the 1-5 key respectively (i.e. B1 = OFF 1 1 # and CB = OFF 2 OFF 1 #).