
Page 38
Z 1 TYPE THROUGH Z 48 TYPE
This item specifies the zone type for each zone. All choices are listed in this manual under DESCRIPTION OF ZONE TYPES.
For zone types, the current setting is shown on the bottom line.
ZONE 1 TYPE: 64
AUXILIARY #=CHNG
THROUGH
ZONE 48 TYPE: 64
AUXILIARY #=CHNG
↑
To change a zone type, press the ' # ' key, then use the arrow keys to scroll through the list of zone types. Press the ' # ' key to
select a new type
.
The display shows:
SELECT TYPE: 1
PERIMETER
ZONE RESPONSE TIME
All zones, in the Omni IIe are set to a 300 millisecond fixed response time.
ZONE TYPES
ZONE TYPE
NUMBER
DESCRIPTION
ENTRY/EXIT
0 Entry/Exit
PERIMETER
1 Perimeter
NIGHT
INT
2 Night
Interior
AWAY
INT
3 Away
Interior
2X ENTRY DELAY
4
Double Entry Delay
4X ENTRY DELAY
5
Quadruple Entry Delay
LATCH
PERIM
6 Latching
Perimeter
LATCH NIGHT INT
7
Latching Night Interior
LATCH AWAY INT
8
Latching Away Interior
PANIC
16
Panic
POLICE
EMERG 17
Police
Emergency
SILENT
DURESS 18
Duress
TAMPER 19
Tamper
LATCH
TAMPER 20
Latching
Tamper
FIRE
32
Fire
FIRE
EMERG
33
Fire
Emergency
GAS
34
Gas Alarm
AUX
EMERG
48
Auxiliary
Emergency
TROUBLE
49
Trouble
FREEZE 54
Freeze
WATER
55
Water
FIRE
TAMPER
56
Fire
Tamper
AUXILIARY
64
Auxiliary
KEY
SWITCH
65
Keyswitch
Input
ENERGY
SAVER 80
Programmable
Energy
Saver
Module
OUTDOOR
TMP
81
Outdoor
Temperature
TEMPERATURE 82
Temperature
TEMP
ALARM
83
Temperature
Alarm
HUMIDITY
84
Humidity
ER OUTDOOR TMP
85
Extended Range Outdoor Temperature
ER TEMPERATURE
86
Extended Range Temperature
ER TEMP ALARM
87
Extended Range Temperature Alarm
Summary of Contents for OMNI IIe
Page 2: ......
Page 21: ...Page 15 BLACK RED RED FIGURE 8 SOUNDER CONNECTIONS...
Page 73: ......
Page 74: ...HAI New Orleans LA U S A...