Page 24
YELLOW
GREEN
A
B
TOP
SIDE
- YELLOW WIRE ON TOP -
4 POSITION MODULAR
PHONE CABLE
- TAB UP -
FIGURE 15 - RS-485 CONNECTIONS
BUILT-IN ETHERNET PORT
Omni IIe has an Ethernet port (J6) built onto the controller (labeled ETHERNET). The Ethernet port allows a device to connect
to the Omni IIe controller via a network (i.e. Ethernet, Internet) using a secure, encrypted communication link. The Ethernet port
transports HAI application-level packets containing Omni-Link serial protocol messages over IP. The controller supports 3
unique client “sessions” which means 3 devices may actively be connected and communicating with the controller simultaneously
over the Ethernet port.
CONTROLLER IP ADDRESS, PORT NUMBER, AND ENCRYPTION KEY
The controller’s local IP address and port number set the local network parameters for the Omni IIe controller. The encryption
key is used to establish a private, secure connection with the connected device.
The following Setup items can only be assigned and changed from an HAI console. These items can not be assigned or changed
via PC Access; although the IP address and port number may be viewed via PC Access:
Summary of Contents for OMNI IIe