67
+
52
Stromflußrichtung
L3
N
L2
L1
F1
10
L1
13
N
-
51
21
l1
20
k1
41
K1
40
C
42
K2
F1
2
N
43
K3
1
L
B
92
A
90
91
K4 K5
44 45
Ha
up
ts
tr
om
Me
sssp
an
nung
31
30
Ne
tz
Temperaturfühler
Relais
C S
Modul
Display
OUT
OUT
Stufen
zu weiteren Busteilnehmern
bzw. Leitungsabschluss
PE
Modbus
SPC06HM
F2
F2
1
2
3
4
Power
SPC04RM
Po
wer
1 2 3 4 5 6
SPC06HM
POWER FACTOR CORRECTION
F1
SPC06HM
POWER FACTOR CORRECTION
F2
F3
F4
cos U/I
T
MM St
U
h
I
h
Extra
F1
POWER FACTOR CORRECTION
F2
F3
F4
cos U/I
T
MM St
U
h
I
h
Extra
0.92
209
SPC06HM
F1
POWER FACTOR CORRECTION
F2
F3
F4
cos U/I
T
MM St
U
h
I
h
Extra
SPC06HM
Technical changes reserved
HTG410H
Power Factor Correction Controller SPC06HM
7.5 Power Factor Correction Controller SPC06HM
The PFC controller is composed of 2 parts, the display which is
flush mounting on the cabinet door, and the main casing which is
a rail mounting product. The RJ12 connection cable between the
2 products is provided and must be connected.
Before switching on the device, please check that the backup battery
(Lithium CR2032), in the main casing product, has been built in.
Otherwise, all stored data would be lost in case of a power failure.
1
Disconnect the device from the supply voltage.
2
Lift the upper housing cover with a suitable tool
(e.g. a small screwdriver).
3
If not built in, push the battery into the clamping bracket
and make sure that it is inserted correctly and has the right
polarity. The (+) must be in front of you.
4
Put the upper housing cover back on and click it into place
by pushing.
5
Reconnect the device to the supply voltage.
Make sure that the power supply and the different connections are
properly connected on the main casing. If you have a doubt, please
consult the SPC06HM instruction manual.
Actual
Targ.
Max
Display Module
to other bus devices
or line connection
Temperaturesensor
Modbus
Relay
Stages
Current flow
Main
Mains
Measuring
7.5.1 Power factor display panel
Modbus connection:
Terminal 91: A (-)
Terminal 92: B (+)
Terminal 90: Common (not Ground)
Reminder : If the controller is integrated into the RS485 daisy chain
network as first or terminal device, a 120 Ω resistor
must be connected between the terminals 91 - 92 “A” and “B“.
Description of buttons and displays
1
Display navigation panel
The navigation panel shows the main menu selected.
2
Unit display
In use mode, the display shows the measured values.
In programming mode, the display area is used to show the menu
and sub menus.
3
Hot key area
The text line corresponds to the respective function keys and is
used to issue messages and text.
F1 to F4 are sensitive touches
1
Display
navigation panel
2
Unit display
3
Hot key area
Actual
Targ.
Max