76
Step2
To improve the upgrading speed, first modify the serial interface baud rate. For more information, see
“
Modifying serial communication parameters
Step3
Select
2
in the serial interface submenu. The following prompt appears:
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCCCCCCC
Step4
Select and send the application file in HyperTerminal. The procedure for upgrading an application file
is the same as upgrading the BootWare. For more information, see “
Upgrading the BootWare through
NOTE:
The size of an application program is typically over 10 MB. Even at the baud rate of 115,200 bps, the
upgrade takes about 30 minutes. Therefore, you are recommended to upgrade an application program
through an Ethernet interface.
Upgrading applications through an Ethernet
interface
Select
3
in the BootWare main menu to enter the Ethernet interface submenu. For more information about
this submenu, see “
Configuring Ethernet interface parameters
Before upgrading an application program through an Ethernet interface, configure the Ethernet interface
of the access controller, as follows.
Select
3
in the BootWare main menu to enter the Ethernet interface submenu. Then, select 5 to enter the
Ethernet interface configuration submenu:
============================<ETHERNET PARAMETER SET>============================
|Note: '.' = Clear field. |
| '-' = Go to previous field. |
| Ctrl+D = Quit. |
================================================================================
Protocol (FTP or TFTP) :tftp
Load File Name :wx6103.bin
Target File Name :wx6103.bin
Server IP Address :192.168.0.179
Local IP Address :192.168.0.1
Gateway IP Address :192.168.0.10
NOTE:
•
When configuring a parameter, you can enter a new value directly, or press
Enter
to accept the default
value that follows a colon. Type
.
to clear the current input,
-
to return to the previous parameter field, and
Ctrl+D
to quit from the parameter configuration interface.
•
The WX6103 access controller supports only the 10/100/1000Base-TX out-of-band management
Ethernet interface for application upgrade.
Summary of Contents for WX6103
Page 10: ...2 Figure 2 Rear panel of the WX6103...
Page 12: ...4 Figure 4 Front panel of the PSR650 D...
Page 13: ...5 Figure 5 Fan structure...
Page 15: ...7 Figure 8 Front panel of the EWPXM1WCMD0...
Page 18: ...10 Figure 10 LEDs on the EWPX1WCMD0...
Page 21: ...13 Figure 12 LEDs on the switch interface board panel...
Page 27: ......
Page 30: ...22 Figure 15 Connect the PGND cable...
Page 31: ...23 Figure 16 Appearance of the PSR650 A...
Page 36: ......
Page 50: ...42 Removing a board Figure 36 Remove a board...
Page 58: ......
Page 74: ......
Page 80: ......
Page 89: ......