54
Step3
Use the
get
and
put
commands to back up and restore files.
# Use the
get
command to download wx6103.bin from the FTP server to the access controller.
[ftp]get wx6103.bin wx6103.bin
cfa0:/wx6103.bin has been existing. Overwrite it? [Y/N]:y
227 Entering passive mode (162,105,25,200,13,226)
125 Using existing data connection
226 Closing data connection; File transfer successful.
FTP: 39709988 byte(s) received in 66.660 second(s), 595.00K byte(s)/sec.
# Use the
put
command to back up wx6103.bin to the FTP server.
[ftp]put wx6103.bin wx6103.bin
227 Entering passive mode (162,105,25,200,14,94)
125 Using existing data connection
226 Closing data connection; File transfer successful.
FTP: 39709988 byte(s) sent in 28.328 second(s), 1401.00Kbyte(s)/sec.
[ftp]quit
Summary of Contents for WX6103
Page 10: ...2 Figure 2 Rear panel of the WX6103...
Page 12: ...4 Figure 4 Front panel of the PSR650 D...
Page 13: ...5 Figure 5 Fan structure...
Page 15: ...7 Figure 8 Front panel of the EWPXM1WCMD0...
Page 18: ...10 Figure 10 LEDs on the EWPX1WCMD0...
Page 21: ...13 Figure 12 LEDs on the switch interface board panel...
Page 27: ......
Page 30: ...22 Figure 15 Connect the PGND cable...
Page 31: ...23 Figure 16 Appearance of the PSR650 A...
Page 36: ......
Page 50: ...42 Removing a board Figure 36 Remove a board...
Page 58: ......
Page 74: ......
Page 80: ......
Page 89: ......