53
Operation scenario
•
Expand the SATA M.2 SSD module.
•
The SATA M.2 SSD module fails.
•
The SATA M.2 SSD module hinders maintenance of other parts
•
Replace the SATA M.2 SSD module with full space.
•
Replace the SATA M.2 SSD module with another model.
Prerequisites
Take the following ESD prevention measures:
•
Wear antistatic clothing.
•
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
•
Do not wear any conductive objects, such as jewelry or watches.
•
Identify the position of the SATA M.2 SSD to be replaced.
•
Identify the RAID array information of the SSD to be replaced. To replace an SSD that is not
configured with a RAID or is in a non-redundancy RAID array, back up all data.
•
Before replacing, make sure that you stop all services and power off the server. For more
information, see "
•
Remove the blade server. For more information, see "
•
When you replace a component, examine the slot and connector for damages. Make sure the
pins are not damaged (bent for example) and do not contain any foreign objects.You might also
remove other components. For the removed components to be reinstalled correctly, record their
positions and connections before removal, for example, taking pictures of cable connection and
drive installation positions, or labeling cables.
•
Understand the installation of SATA M.2SSD module, see”
.”
Removing a SATA M.2 SSD module
Hold a SATA M.2 SSD module by its handle, and pull the module out from the slot.
Installing a SATA M.2 SSD module
1.
Insert the SATA M.2 SSD module into the adapter module.
2.
(Optional.) Power on the blade server. For more information, see "