Figure 52
Replacing an LPU (2)
Replacing a switching fabric module
1.
Prepare an antistatic mat to place the removed switching fabric module.
2.
Wear an ESD wrist strap, and make sure it makes good skin contact and is reliably grounded. For
more information, see "
3.
Use a Phillips screwdriver to loosen the captive screws on the switching fabric module, as shown
in callout 1 on
.
4.
Press the buttons on the ejector levers to release them and then move the ejector levers outward to
separate the switching fabric module from the backplane, as shown in callout 2 on