Installation Manual
H3C S5600 Series Ethernet Switches
Chapter 1 Product Overview
1-19
Item
S5600-
26C
S5600-26C
-PWR
S5600-26F
S5600-
50C
S5600-
50C-PWR
Power
module
PSL130-AD: 130 W system output, AC/DC input
PSL480-AD24P: 24-port PoE power module, 180 W system
300 W PoE output (AC input); 180 W system
370 W PoE output (DC input)
PSL180-AD: 180 W system output, AC/DC input
PSL480-AD48P: 48-port PoE power module, 180 W system
300 W PoE output (AC input); 180 W system
740 W PoE output (DC input)
The input voltage of the AC/DC dual input power module:
AC input:
Rated voltage: 100 VAC to 240 VAC, 50 Hz or 60Hz
Maximum tolerance:90 VAC to 264 VAC, 50 Hz or 60Hz
DC input:
Rated voltage:
–
48 VDC to
–
60 VDC
Maximum tolerance:
–
36 VDC to
–
72 VDC
Input
voltage
The AC input of the PoE power module:
Rated voltage: 100 VAC to 240 VAC, 50 Hz or 60 Hz
Max voltage range: 90 VAC to 264 VAC, 50 Hz or 60 Hz
The DC input of the PoE power module:
Rated voltage:
–
53.5 VDC
Max voltage range:
–
52 VDC to
–
55 VDC
For S5600-26C-PWR/S5600-50C-PWR, use the external RPS
recommended by H3C as the DC power input instead of the
–
48 VDC power supply generally available in the equipment
room. Any violation may damage the device due to overvoltage.
Power
supply
RPS
power
Supported
Power
consumption (full
load)
170W
540W
When with
PoE power
supply:
540 W (DC
input),
560 W (AC
input)
170W 230W
600W
When with
PoE
power
supply:
970 W
(DC input),
640 W (AC
input)