Installation Manual
H3C S5100-SI/EI Series Ethernet Switches
Chapter 5 Boot ROM and Host Software Loading
5-4
Enter your choice(0-3):
Step 2: Enter 3 in the above menu to load the Boot ROM software using XModem. The
system displays the following download baud rate setting menu:
Please select your download baudrate:
1.* 9600
2. 19200
3. 38400
4. 57600
5. 115200
0. Return
Enter your choice (0-5):
Step 3: Choose an appropriate download baud rate. For example, if you enter 5, the
115200 bps rate is chosen, and the system displays the following information:
Download baudrate is 115200 bps
Please change the terminal's baudrate to 115200 bps and select XMODEM protocol
Press enter key when ready
Now, press <Enter>.
Note:
If you have chosen 9600 bps, you do not need to modify the HyperTerminal’s baud rate,
and therefore you can skip Step 4 and 5 below and proceed to Step 6 directly. In this
case, the system will not display the above information.
Step 4: Choose [File/Properties] in HyperTerminal, click <Configuration> in the popup
dialog box, select the baud rate of 115200 bps in the appeared console port
configuration dialog box.