GYS WS-4L Manual Download Page 9

WS-4R / WS-4L

EN

FIRE AND EXPLOSIONS RISKS

Protect the entire welding area. Compressed gas containers and other inflammable material must be moved to a minimum safe 

distance of 11 meters. 

A fire extinguisher must be readily available.

Be careful of spatter and sparks, even through cracks. It can be the source of a fire or an explosion.

Keep people, flammable objects and containers under pressure at a safe distance.

Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any inflammable or explosive 

materials (oil, petrol, gas...). 

Grinding operations should not be directed towards the device itself, the power supply or any flammable materials.

GAS BOTTLE

Gas leaking from the cylinder can create a hazard if present in high concentrations around the work area.

Transport must be done safely: Cylinders closed and product off. Always keep cylinders in an upright position securely chained 

to a fixed support or trolley.

Close the bottle after any welding operation. Be careful with gas bottles placed in areas of high temperature, or in sunlight.

Cylinders should be located away from areas where they may be struck or subjected to physical damage.

Always keep gas bottles at a safe distance from arc welding or cutting operations, and any source of heat, sparks or flame.

Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make sure the gas meets your welding 

requirements.

ELECTRIC SAFETY

The machine must be connected to an earthed electrical supply. Use the recommended fuse size.

An electrical discharge can directly or indirectly cause serious or deadly accidents.

Do not touch any live part of the machine (inside or outside) when it is plugged in (Torches, earth cable, cables, electrodes) because they are 

connected to the welding circuit.

Before opening the device, it is imperative to disconnect it from the mains and wait 2 minutes, so that all the capacitors are discharged.

Do not touch the torch or electrode holder and earth clamp at the same time.

Damaged cables and torches must be changed by a qualified and skilled professional.

Make sure that the cable cross section is adequate with the usage (extensions and welding cables).

Always wear dry clothes in good condition, in order to be insulated from the electrical circuit. Wear insulating shoes, regardless of the environment 

in which you work in.

EMC CLASSIFICATION

These Class A devices are not intended to be used on a residential site where the electric current is supplied by the public 

network, with a low voltage power supply. There may be potential difficulties in ensuring electromagnetic compatibility on these 

sites, because of the interferences, as well as radio frequencies.

These devices are not compliant with the CEI 61000-3-12 standard. On a public low-voltage power grid, it is the responsibility 

of the installer or user of the device to ensure, by checking with  the operator of the distribution network, which device can be 

connected.

ELECTROMAGNETIC INTERFERENCES

The electric currents flowing through a conductor cause electrical and magnetic fields (EMF). The welding current generates an 

EMF field around the welding circuit and the welding equipment.

The EMF fields may disrupt some medical implants, such as pacemakers. Protection measures should be taken for people wearing medical implants. 

For example, access restrictions for passers-by or an individual risk evaluation for the welders.

All welders should take the following precautions in order to minimise exposure to the electromagnetic fields (EMF) generated by the welding circuit::

– position the welding cables together – if possible, attach them;

– keep your head and torso as far as possible from the welding circuit;

– never enroll the cables around your body;

– never position your body between the welding cables. Hold both welding cables on the same side of your body;

– connect the earth clamp as close as possible to the area being welded;

– do not work too close to, do not lean and do not sit on the welding machine

– do not weld when you’re carrying the welding machine or its wire feeder.

9

Summary of Contents for WS-4L

Page 1: ...73502 V6 04 07 2018 FR EN DE 2 3 7 22 25 2 8 12 22 25 2 13 17 22 25 WS 4R WS 4L ES 2 18 21 22 25...

Page 2: ...WS 4R WS 4L III II I 3 1 2 4 7 5 6 2 1 3 2 5 4 6 8 7 9 10 500 WS 500 WS 400 500 GR 13 M5x10 x4 M6x20 x3 11 12...

Page 3: ...sans revers isolants secs ignifug s et en bon tat qui couvrent l ensemble du corps Utiliser des gants qui garantissent l isolation lectrique et thermique Utilisez une protection de soudage et ou une...

Page 4: ...ne jamais souder une bouteille sous pression Attention lors de l ouverture du robinet de la bouteille il faut loigner la t te de la robinetterie et s assurer que le gaz utilis est appropri au proc d...

Page 5: ...triques et causer des chauffements de composants pouvant entrainer un incendie Toutes les connexions de soudages doivent tre connect es fermement v rifiez r guli rement S assurer que la fixation de la...

Page 6: ...monter sur le g n rateur PRESENTATION I 1 Support bobine 200 300mm 2 Moto d vidoir 3 Poign e de transport 4 Potentiom tre de vitesse de fil 5 Connecteur torche Euro 6 El ment sup rieur de la tourelle...

Page 7: ...adapt e l appareil Le d bit du fil n est pas constant Le fil patine dans les galets Resserrer la vis du frein de la bobine de fil Frein de bobine trop serr Desserrer en agissant sur la vis de frein d...

Page 8: ...tion Use sufficient welding protective gear for the whole body hood gloves jacket trousers variable depending on the application operation Protect your eyes during cleaning operations Do not operate w...

Page 9: ...ors are discharged Do not touch the torch or electrode holder and earth clamp at the same time Damaged cables and torches must be changed by a qualified and skilled professional Make sure that the cab...

Page 10: ...IP23S which means Protection against acess to dangerous parts from solid bodies of a 12 5mm diameter and Protection against the rain inclined at 60 towards the vertical These devices can be used outsi...

Page 11: ...S Generator Fix power cable with holding device Fig 2 13 Adapt the sheath on the base and tighten hose clip WIRE REEL INSTALLATION III Open the door of the machine Position the reel on to the support...

Page 12: ...th crushed Change it Roller grooves do not match the diameter of wire used Change for size suitable for wire used The wire speed potentiometer is not working The button on the separate wire feeder is...

Page 13: ...Lichtbogens kann zu schweren Augensch den und Hautverbrennungen f hren Die Haut muss durch geeignete trockene Schutzbekleidung Schwei erhandschuhe Ledersch rze Sicherheitsschuhe gesch tzt werden Trage...

Page 14: ...Verbrennungen verursachen Ber hren Sie daher UNTER KEINEN UMST NDEN Teile des Ger teinneren oder das ge ffnete Geh use wenn das Ger t mit dem Stromnetz verbunden ist Trennen Sie IMMER das Ger t vom St...

Page 15: ...ie das Hebensystem um die Isolierung zu sichern Stellen Sie keine Bohrmaschine keines Schleifger t usw auf das Schwei ger t der Fahrwagen oder das Hebensystem hin wenn sie nicht isoliert sind Stellen...

Page 16: ...hl uche Anschluss an 13 und 14 Fixieren Sie das Leistungskabel mit Hilfe der Kabelklemme 15 am Drahtvorschubkoffer MONTAGE DER DRAHTROLLEN ABB III Entfernen Sie die Seitenverkleidung des Ger tes danac...

Page 17: ...r t ffnen und schalten Sie die Anlage wenn n tig T glich Pr fen Sie den Brenner die Drahtf hrungsrollen und die Anschl sse Zwei Mal pro Jahr das Innere des Ger tes mit Druckluft reinigen Achtung keine...

Page 18: ...t rmico Utilice una protecci n de soldadura y o una capucha de soldadura de un nivel de protecci n suficiente variable seg n aplicaciones Prot jase los ojos durante operaciones de limpieza Las lentil...

Page 19: ...rga el ctrica puede ser una fuente de accidente grave directo o indirecto incluso mortal No toque nunca las partes bajo tensi n tanto en el interior como en el exterior del aparato cuando este est enc...

Page 20: ...elevado sin que est n aislados Coloque siempre las antorcha de soldadura o los portaelectrodos sobre una superficie aislada cuando no est n siendo utilizados INSTALACI N DEL MATERIAL Ajuste a seguir L...

Page 21: ...nillo de fijaci n Para ajustar la presi n de los rodillos Desafloje la ruedecilla 7 al m ximo b jela inserte el hilo y cierre la devanadera Accione el motor presionando el gatillo de la antorcha Aprie...

Page 22: ...H J K 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 10K 24Vdc 75W 24Vdc Max 0 5A Max 24Vac 50 60Hz 11VA Max Min M 3 94895 94894 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3...

Page 23: ...ansportgriffe Mango delantero 56047 9 Electrovanne Solenoid valve Buchse Schutzgasanschluss Electrov lvula 71512 10 Connecteur de commande Connector Buchse Steuerkabel Conector de mando 94894ST 11 Con...

Page 24: ...1 Einschaltdauer 40 C 10 min EN60974 1 Norm 40 C 10 EN60974 1 Ciclo di lavoro a 40 C 10 min Norma EN60974 1 Inschakelduur bij 40 C 10 min Norm EN60974 1 60 410A 100 320A Gaz de protection Protectice g...

Page 25: ...d claration de conformit est disponible sur notre site internet Machine s compliant with European directives The declaration of conformity is available on our website Dieses Ger t entspricht den europ...