background image

WS-4R / WS-4L

EN

People wearing pacemakers are advised to consult their doctor before using this device.

Exposure to electromagnetic fields while welding may have other health effects which are not yet known.

TRANSPORT AND TRANSIT OF THE WIRE FEEDER

The wire feeder is equipped with handles for easy transportation. Be careful not to underestimate the machine’s weight. The handle cannot be used 

to hang the machine from other equipment. Never lift the machine while there is a gas cylinder on the support shelf. A clear path is available when 

moving the item.

Do not place/carry the unit over people or objects.

The removal of the wire reel from the machine is recommended before undertaking any lifting operation.

The machine is fitted with non-insulated lifting eye bolts, they are designed for wire feeder maintenance and not for wire feeder lifting during welding 

operations.  If they are used during welding, the eye bolts must be insulated from the building’s earth.

Stray welding currents/voltages may destroy earth conductors, damage electrical equipment or cause components to warm up which 

may cause a fire.

- All welding connections must be firmly secured, check regularly !

- Check that the metal piece fixation is strong and without any electrical problems !

- Attach or hang all the electrically conductive elements,such as the trolley in order to insulate them  

- Do not place any electrical equipment such as drills on top of the welding machine without insulating them !

- Always place welding torches or electrodes holders on an insulated surface when they’re not in use !

INSTALLATION

ules to follow :

• The wire feeder must be switched on with all access panels closed. 

• Put the wire feeder on a floor with a maximum incline of 10°.

• The machine must be placed in a sheltered area away from rain or direct sunlight.

• The equipment’s protection level is IP23S, which means :

- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,

- Protection against the rain inclined at 60% towards the vertical.

These devices can be used outside in accordance with the IP23S protection index.

The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect 

and/or dangerous use of the machine .

MAINTENANCE / RECOMMENDATIONS

• Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.

• Ensure the wire feeder is disconnected from the welding machine, and wait for two minutes before carrying out maintenance 

work.

• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified 

person, with an insulated tool.

• Regularly check the connection cable between the wire feeder and the machine. If damaged, the connection cable cable must be replaced.

• Warning !  If the welding machine is transported/handled by another solution than the one recommended by the manufacturer; the wire feeder 

casing must be insulated from the transporting/handling solution.

Rules to follow :

• The wire feeder must be switched on with all access panels closed.

INSTALLATION – PRODUCT OPERATION

Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment.  During set up, 

the operator must ensure that the machine is unplugged.

Risk of injury due to moving parts!

The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries! Take extra care. 

• Do not place your hand on mobile/pivoting/wire feeding parts of the machine!

• Make sure that all panels remain closed when in use !

DESCRIPTION

The WS4L is a wire feeder suitable for a water cooled torch and designed for use with MIG WS 500. THE WS4R wire feeder is suitable for MIG 400 

GR / 500 GR. They work with 200mm reels and 300mm reels.

The unit comes with a swivel support to be mounted on the generator.

10

Summary of Contents for WS-4L

Page 1: ...73502 V6 04 07 2018 FR EN DE 2 3 7 22 25 2 8 12 22 25 2 13 17 22 25 WS 4R WS 4L ES 2 18 21 22 25...

Page 2: ...WS 4R WS 4L III II I 3 1 2 4 7 5 6 2 1 3 2 5 4 6 8 7 9 10 500 WS 500 WS 400 500 GR 13 M5x10 x4 M6x20 x3 11 12...

Page 3: ...sans revers isolants secs ignifug s et en bon tat qui couvrent l ensemble du corps Utiliser des gants qui garantissent l isolation lectrique et thermique Utilisez une protection de soudage et ou une...

Page 4: ...ne jamais souder une bouteille sous pression Attention lors de l ouverture du robinet de la bouteille il faut loigner la t te de la robinetterie et s assurer que le gaz utilis est appropri au proc d...

Page 5: ...triques et causer des chauffements de composants pouvant entrainer un incendie Toutes les connexions de soudages doivent tre connect es fermement v rifiez r guli rement S assurer que la fixation de la...

Page 6: ...monter sur le g n rateur PRESENTATION I 1 Support bobine 200 300mm 2 Moto d vidoir 3 Poign e de transport 4 Potentiom tre de vitesse de fil 5 Connecteur torche Euro 6 El ment sup rieur de la tourelle...

Page 7: ...adapt e l appareil Le d bit du fil n est pas constant Le fil patine dans les galets Resserrer la vis du frein de la bobine de fil Frein de bobine trop serr Desserrer en agissant sur la vis de frein d...

Page 8: ...tion Use sufficient welding protective gear for the whole body hood gloves jacket trousers variable depending on the application operation Protect your eyes during cleaning operations Do not operate w...

Page 9: ...ors are discharged Do not touch the torch or electrode holder and earth clamp at the same time Damaged cables and torches must be changed by a qualified and skilled professional Make sure that the cab...

Page 10: ...IP23S which means Protection against acess to dangerous parts from solid bodies of a 12 5mm diameter and Protection against the rain inclined at 60 towards the vertical These devices can be used outsi...

Page 11: ...S Generator Fix power cable with holding device Fig 2 13 Adapt the sheath on the base and tighten hose clip WIRE REEL INSTALLATION III Open the door of the machine Position the reel on to the support...

Page 12: ...th crushed Change it Roller grooves do not match the diameter of wire used Change for size suitable for wire used The wire speed potentiometer is not working The button on the separate wire feeder is...

Page 13: ...Lichtbogens kann zu schweren Augensch den und Hautverbrennungen f hren Die Haut muss durch geeignete trockene Schutzbekleidung Schwei erhandschuhe Ledersch rze Sicherheitsschuhe gesch tzt werden Trage...

Page 14: ...Verbrennungen verursachen Ber hren Sie daher UNTER KEINEN UMST NDEN Teile des Ger teinneren oder das ge ffnete Geh use wenn das Ger t mit dem Stromnetz verbunden ist Trennen Sie IMMER das Ger t vom St...

Page 15: ...ie das Hebensystem um die Isolierung zu sichern Stellen Sie keine Bohrmaschine keines Schleifger t usw auf das Schwei ger t der Fahrwagen oder das Hebensystem hin wenn sie nicht isoliert sind Stellen...

Page 16: ...hl uche Anschluss an 13 und 14 Fixieren Sie das Leistungskabel mit Hilfe der Kabelklemme 15 am Drahtvorschubkoffer MONTAGE DER DRAHTROLLEN ABB III Entfernen Sie die Seitenverkleidung des Ger tes danac...

Page 17: ...r t ffnen und schalten Sie die Anlage wenn n tig T glich Pr fen Sie den Brenner die Drahtf hrungsrollen und die Anschl sse Zwei Mal pro Jahr das Innere des Ger tes mit Druckluft reinigen Achtung keine...

Page 18: ...t rmico Utilice una protecci n de soldadura y o una capucha de soldadura de un nivel de protecci n suficiente variable seg n aplicaciones Prot jase los ojos durante operaciones de limpieza Las lentil...

Page 19: ...rga el ctrica puede ser una fuente de accidente grave directo o indirecto incluso mortal No toque nunca las partes bajo tensi n tanto en el interior como en el exterior del aparato cuando este est enc...

Page 20: ...elevado sin que est n aislados Coloque siempre las antorcha de soldadura o los portaelectrodos sobre una superficie aislada cuando no est n siendo utilizados INSTALACI N DEL MATERIAL Ajuste a seguir L...

Page 21: ...nillo de fijaci n Para ajustar la presi n de los rodillos Desafloje la ruedecilla 7 al m ximo b jela inserte el hilo y cierre la devanadera Accione el motor presionando el gatillo de la antorcha Aprie...

Page 22: ...H J K 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 10K 24Vdc 75W 24Vdc Max 0 5A Max 24Vac 50 60Hz 11VA Max Min M 3 94895 94894 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3...

Page 23: ...ansportgriffe Mango delantero 56047 9 Electrovanne Solenoid valve Buchse Schutzgasanschluss Electrov lvula 71512 10 Connecteur de commande Connector Buchse Steuerkabel Conector de mando 94894ST 11 Con...

Page 24: ...1 Einschaltdauer 40 C 10 min EN60974 1 Norm 40 C 10 EN60974 1 Ciclo di lavoro a 40 C 10 min Norma EN60974 1 Inschakelduur bij 40 C 10 min Norm EN60974 1 60 410A 100 320A Gaz de protection Protectice g...

Page 25: ...d claration de conformit est disponible sur notre site internet Machine s compliant with European directives The declaration of conformity is available on our website Dieses Ger t entspricht den europ...