SAFETY
INSTRUCTIONS
7
Cleaning
GDM-8200 series
•
Disconnect the power cord before cleaning.
•
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid into
GDM-8200 series.
•
Do not use chemical or cleaner containing harsh
material such as benzene, toluene, xylene, and acetone.
•
Location: Indoor, no direct sunlight, dust free, almost
non-conductive pollution (Note below)
•
Relative Humidity: < 75%
•
Altitude: < 2000m
•
Temperature: 0°C to 40°C (operation), 18°C to 28°C
(full accuracy)
Operation
Environment
(Note) EN 61010-1:2001 specifies the pollution degrees and their
requirements as follows. GDM-8200 series falls under degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
•
Pollution degree 1: No pollution or only dry, non-conductive pollution
occurs. The pollution has no influence.
•
Pollution degree 2: Normally only non-conductive pollution occurs.
Occasionally, however, a temporary conductivity caused by
condensation must be expected.
•
Pollution degree 3: Conductive pollution occurs, or dry,
non-conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment is
normally protected against exposure to direct sunlight, precipitation,
and full wind pressure, but neither temperature nor humidity is
controlled.
Storage
Environment
•
Location: Indoor
•
Relative Humidity: < 75% (0~35°C), <50% (35~50°C)
•
Temperature:
−
10°C to 70°C
GDM-8200 Series User Manual
8
Power cord for the United Kingdom
When using GDM-8200 series in the United Kingdom, make sure the power
cord meets the following safety instructions.
NOTE: This lead / appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Green/ Yellow: Earth
Blue: Neutral
Brown: Live
(Phase)
As the colours of the wires in main leads may not correspond with the
colours marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth
terminal marked with the letter E or by the earth symbol or coloured Green
or Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is
marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked
with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact
the supplier.
This cable/appliance should be protected by a suitably rated and approved
HBC mains fuse: refer to the rating information on the equipment and/or
user instructions for details. As a guide, cable of 0.75mm2 should be
protected by a 3A or 5A fuse. Larger conductors would normally require 13A
types, depending on the connection method used.
Any moulded mains connector that requires removal /replacement must be
destroyed by removal of any fuse & fuse carrier and disposed of immediately,
as a plug with bared wires is hazardous if a engaged in live socket. Any
re-wiring must be carried out in accordance with the information detailed on
this label.