5.1 Removing Blower Housing Face
Review the safety section of this manual before attempt-
ing these procedures.
Thoroughly read and understand the safety and
pre-operating sections of this manual before work-
ing on the unit.
figure 5.1a
Raise the dump body and secure it as described
previously in this manual, making sure the body
prop(s) is in place.
Unbolt the 4 bolts holding the intake hose flange
assembly to the blower housing face (figure 5.1a).
and remove the hose assembly.
Remove the frame bolts (figure 5.1a)
Loosen the bolt that's behind the boom mast,
which holds the frame to the housing. Swing the
bolt and sping up and out of the slot. (figure 5.1b)
The frame should swing open on the hinge.
Remove the housing bolts from the housing face
to gain access to the impeller.
To install reverse the above procedure.
Removing Blower Housing Face (refer to 5.1a and
5.1b):
1.
2.
3.
4.
5.
6.
7.
Make sure the negative battery cable is discon-
nected before opening the blower housing.
figure 5.1b